gas water heater control board Function description
1) It works with a display.
2) It works with a ventilator.
3) It works with a on-off valve, a proportional valve and a section valve.
4) It is with a buzzer.
5) It has AC ionization flame signal detection.
6) Status keeping function: If the nP menu was set as ON, after power on again, the system
will return to the last status before the power is cut off.
7) Flue pipe block-up protection.
8) Malfunction protection and warning function.
9) Compliance with Standard: BS EN298: 2012. ANSI Z21.20 -2014. CAN/CSA C22.2 No. 60730-2-5-2014.
More information you can click here
Main technical parameters |
|
Working voltage range |
90VAC ~ 120VAC |
Rated voltage |
120VAC 60Hz |
Power frequency |
50/60Hz±5% |
Rated frequency |
50Hz |
Dielectric strength(V/1min) |
1800V, 0.5mA, 3S |
Working ambient temperature |
-10℃~70℃ |
Ambient temperature |
-20℃~70℃ |
Life cycle |
≥50,000 times |
Temperature setting range |
35-65℃ |
High temperature protection |
when the output water temperature ≥85℃ for 3S |
Pre- cleaning time |
2S |
After cleaning time |
20s |
Start-up water flow |
≤3L/min |
Closing water flow |
≤2.5L/min |
Ignition time |
8±1S |
Cleaning time before 2nd ignition |
3S |
Max. allowable No. of ignition |
2 |
Valve moving pulse |
0.5±0.05S |
24V Valve open voltage |
≥24V |
24V Valve holding voltage |
≥8.5V |
Output voltage of switch power supply |
5VDC (with 300mA working current) |
30±1.5VDC(with 510mA working current) |
|
12±1VDC(with 110mA working current) |
|
Ion sensibility of flame detection |
≥5.1MΩ |
Temperature detection precision |
±2℃ |
Waiting time of reaching setted temperature |
≤35S |
Water temperature overshoot range |
±3℃ |
Timing tolerance |
±1 minutes |
Post-purge time |
20±2s |
Time to achieve safe shut down |
<1s |
Trial for ignition period |
7.5±1s |
Please fill in the below form with your query and we will get back to you.
Reviews of CSA approval Constant Temperature Water Heater Control Board BW-HK002R Abbotsford
Added on : 2022-07-21 11:00 AM
Added on : 2022-08-12 6:31 AM
Added on : 2023-01-11 6:19 AM
Added on : 2018-05-12 12:49 AM
202, Parvati Niwas, Ahilyadevi Holkar Marg, Talaopali, Thane, Maharashtra 400602, India
2nd Floor, UCO Bank Building Yamuna Nagar, Haryana 135001, India
Added on : 2017-07-01 2:55 AM
Added on : 2024-04-26 6:49 AM
Added on : 2024-04-26 5:27 AM
1st Floor, FF - 3 - Jeevan Sagar Complex, Opp. Urban Health Center, Khokhra, Ahmedabad, Gujarat 380008, India
Added on : 2024-04-25 12:54 PM